LABORATORY ANALYSIS OVERVIEW
Each capsule is labeled as 15 mg of RAD-140.
Actual tested content is 14.28 mg/CAP, falling within typical formulation tolerance ranges for experimental-grade compounds.
HPLC-UV/VIS, ensuring compound specificity and quantitation through spectral analysis.
The chromatogram shows a major peak at around 6.72 min, confirming identity with minimal co-eluting substances.
Lot: 0027
Lab ID: V250611-16 006
Date: 06/28/2025
Results are valid only for the tested sample. As per ISO standards, the entire batch cannot be assumed equivalent unless separately validated.